D:\Website\Project papers & books References\Fireproofing\FIREPROOFING 3.jpg

Fireproofing Details

Fireproofing, also known as fire-resistive protection, is crucial for structural elements in buildings to prevent collapse and provide safety during a fire. The American codes, such as the International Building Code (IBC), American Society for Testing and Materials (ASTM) standards, and NFPA 221, offer guidelines for fireproofing structural elements like steel beams, columns, and floors.

1. Spray-Applied Fire-Resistive Materials (SFRM)

  • Description: SFRM is one of the most common fireproofing methods. It involves spraying a coating material, typically a cementitious or fiber-based substance, onto steel or other structural elements. It acts as an insulator, slowing down the temperature rise during a fire.
  • Uses: Primarily used for steel beams, columns, and decks in high-rise buildings and industrial structures.
  • Advantages: Economical, easy to apply on large surfaces, and effective for covering irregular surfaces.
  • Examples: Mineral wool, vermiculite, or gypsum-based fireproofing materials.

D:\Website\Project papers & books References\Fireproofing\FIREPROOFING 1.jpg

2. Intumescent Coatings

  • Description: Intumescent coatings are paint-like materials that expand when exposed to high temperatures, forming an insulating char layer. This layer protects the structural elements by delaying the heat transfer during a fire.
  • Uses: Commonly used on exposed steel structures in buildings where aesthetics are important, such as commercial and residential buildings.
  • Advantages: Thin, smooth finish, often used where architectural appearance matters.
  • Examples: Fire-retardant paints, epoxy intumescent coatings.

3. Concrete Fireproofing

  • Description: Encasing steel columns or beams in concrete provides natural fire resistance. Concrete has good insulating properties and delays the rise in temperature, protecting the structural elements from fire.
  • Uses: Used in high-rise buildings, industrial plants, and bridges.
  • Advantages: Inherently fire-resistant, provides additional strength, durability, and requires less maintenance.
  • Disadvantages: Heavy, bulky, and may be difficult to apply on retrofitting projects.

D:\Website\Project papers & books References\Fireproofing\FIREPROOFING 2 notes.jpg

4. Rigid Board Fireproofing

  • Description: This method involves applying rigid fireproofing boards made from materials like gypsum, calcium silicate, or mineral wool to the surface of the structure. The boards are attached using screws, clips, or adhesives.
  • Uses: Suitable for protecting steel columns and beams, and also for fireproofing mechanical ducts, electrical rooms, and enclosures.
  • Advantages: Easy to install, provides insulation, and can also serve as a thermal barrier.
  • Examples: Gypsum-based or calcium silicate fireproofing boards.

5. Fire-Resistant Gypsum or Plaster

  • Description: Gypsum or plaster-based materials are commonly used in fire-rated wall assemblies, ceilings, and partitions. They provide fire resistance by delaying the passage of heat and flames.
  • Uses: Often used in interior wall construction, fire-rated partitions, and ceilings.
  • Advantages: Cost-effective, easy to apply, and lightweight.
  • Examples: Gypsum wallboard (drywall) used in fire-rated assemblies, plaster coatings.

6. Fireproofing Wraps or Blankets

  • Description: Fireproofing wraps consist of flexible insulation blankets made from fire-resistant materials. They are wrapped around pipes, ducts, or cables to protect against heat and fire.
  • Uses: Commonly used in protecting HVAC ducts, electrical cables, or industrial piping systems from fire.
  • Advantages: Easy to install, flexible, and can fit around complex shapes and installations.
  • Examples: Ceramic or mineral wool blankets, fire-resistant wraps for cable protection.

7. Fireproof Cladding or Encasement

  • Description: This involves covering structural members with protective cladding or encasing them in fire-resistant materials such as gypsum, concrete, or masonry. The cladding serves as a barrier between the structure and the heat of a fire.
  • Uses: Structural beams, columns, and walls in commercial and industrial buildings.
  • Advantages: Provides long-lasting fire protection and can be aesthetically integrated into the design.
  • Examples: Brick, stone, or gypsum panels applied to structural elements.

8. Firestopping

  • Description: Firestopping refers to sealing openings and joints in fire-rated walls, floors, and ceilings to prevent the spread of fire, smoke, and heat. Special fire-resistant materials like caulks, sprays, and sealants are used to close gaps around pipes, cables, and ducts.
  • Uses: Used in wall penetrations, cable trays, and pipe penetrations in fire-rated walls and floors.
  • Advantages: Maintains the integrity of fire barriers and slows down fire and smoke propagation.
  • Examples: Fire-resistant sealants, intumescent caulks, and firestopping putty.

D:\Website\Project papers & books References\Fireproofing\FIREPROOFING 3.jpg

9. Endothermic Fireproofing

  • Description: Endothermic fireproofing materials absorb heat during a fire and release water vapor to cool down the structure. They can be applied as coatings, wraps, or panels.
  • Uses: Typically used for protecting critical electrical or communication systems, piping, and structural members.
  • Advantages: Offers high fire resistance and protects systems that need to remain operational during a fire.
  • Examples: Endothermic mats or panels used in fire barriers for cables and critical equipment.

10. Penetration Fireproofing

  • Description: Penetration fireproofing involves sealing penetrations in walls, floors, and ceilings (such as where pipes or cables pass through) with fire-resistant materials to prevent the spread of fire.
  • Uses: Used in fire-rated assemblies in commercial and industrial buildings.
  • Advantages: Helps maintain the fire-resistance rating of walls and floors.
  • Examples: Fire collars, fire-rated sealants, and intumescent products.

Selection Criteria for Fireproofing:

  • Building Type: Residential, commercial, or industrial applications may require different fireproofing methods.
  • Aesthetic Requirements: For exposed steel elements in architectural designs, thin-film intumescent coatings are often preferred.
  • Fire-Resistance Rating: Depending on building codes (such as IBC or NFPA), a fire-resistance rating of 1, 2, or more hours may be required.
  • Cost: SFRM is usually more economical for large industrial buildings, while intumescent coatings are more costly but offer aesthetic benefits.

Codes and Standards for Fireproofing in the USA:

  • International Building Code (IBC): Defines fire-resistance requirements and fireproofing standards for various building elements.
  • NFPA 221: Standard for Fire Walls and Fire Barrier Walls.
  • ASTM E119: Standard for testing the fire resistance of building elements.
  • UL 263: Fire-resistance rating standard for assemblies and structures.
  • UL 1709: Standard for rapid rise fire tests of protection materials for structural steel.

By choosing the appropriate type of fireproofing based on building needs, regulations, and material properties, you can ensure both structural integrity and safety in the event of a fire.

Fireproofing thickness calculations are based on factors such as the fire-resistance rating required, the type of fireproofing material, the structural element being protected, and the applicable building codes and standards. Here’s an outline of how fireproofing thickness is typically calculated:

Steps for Fireproofing Thickness Calculation:

  1. Determine the Required Fire-Resistance Rating:
    • The fire-resistance rating (e.g., 1 hour, 2 hours, 3 hours) is specified based on building codes such as the International Building Code (IBC), NFPA, or local regulations.
    • Ratings depend on factors like the building type, occupancy, structural element, and location.
  2. Identify the Structural Element to be Protected:
    • Different elements such as steel beams, columns, concrete slabs, and floors require different fireproofing thicknesses.
    • For example, steel structures are more vulnerable to fire and need more protection compared to concrete.
  3. Select the Fireproofing Material:
    • Common materials include:

      • Spray-Applied Fire-Resistive Material (SFRM) (cementitious or mineral fiber-based).
      • Intumescent coatings (thin-film paints).
      • Concrete encasement.
      • Fire-resistant gypsum board or cladding.
    • Different materials provide varying degrees of fire protection at different thicknesses.
  4. Use Fireproofing Thickness Charts and Data:
    • Most fireproofing manufacturers provide thickness charts based on ASTM E119 or UL 263 fire test standards. These charts specify the required thickness for achieving different fire-resistance ratings for various materials.
    • Intumescent coatings, for example, will often have manufacturer-specific guidelines for thickness based on steel section factor (Hp/A or W/D ratio).
  5. Calculate the Section Factor (for Steel Elements):
    • The Section Factor (Hp/A or W/D ratio) is critical for determining the thickness of fireproofing on steel members.

      • Hp is the perimeter of the exposed steel member.
      • A is the cross-sectional area of the steel member.
      • A higher Hp/A ratio means more surface area is exposed to heat, requiring more fireproofing.
    • The required fireproofing thickness increases with higher section factors to maintain the same fire-resistance rating.
  6. Apply Adjustments for Environmental Factors:
    • Additional thickness may be needed if the environment is more severe, such as outdoor conditions (weathering, moisture), or for industrial applications.
    • Codes and standards may specify specific adjustments for such conditions.

Example of Fireproofing Thickness Calculation for Steel (SFRM):

Suppose you need to provide 2-hour fire protection for a steel column using Spray-Applied Fire-Resistive Material (SFRM).

  1. Fire-Resistance Requirement: 2 hours.
  2. Section Factor (Hp/A or W/D): Let’s assume the section factor is calculated or provided.
  3. Consult Manufacturer’s Chart: The chart indicates that for a 2-hour rating and a specific section factor, the required thickness of the SFRM is 25 mm (1 inch).
  4. Adjustments: If the structure is in an outdoor environment, an additional 5 mm may be required to account for weather exposure, increasing the thickness to 30 mm.

Example of Intumescent Coating Thickness Calculation:

For exposed steel beams requiring 1-hour fire resistance:

  1. Fire-Resistance Requirement: 1 hour.
  2. Section Factor (Hp/A): Calculated based on the exposed perimeter and cross-sectional area of the steel beam.
  3. Consult Manufacturer’s Thickness Chart: According to the chart, for a section factor of 100, the required intumescent coating thickness is 0.5 mm.
  4. Adjustments: If exposed to severe conditions (such as outdoor applications), the manufacturer might recommend adding 0.1 mm, increasing the total thickness to 0.6 mm.

Calculation Based on Standards:

  • ASTM E119 or UL 263: These standards provide testing procedures for determining the fire-resistance rating and specify the performance requirements.
  • American Institute of Steel Construction (AISC) provides guidelines on fireproofing thickness for structural steel.

Common Codes and Standards:

  • International Building Code (IBC): Specifies fire-resistance ratings for different building types and structural elements.
  • ASTM E119: Standard test methods for fire tests on building materials.
  • UL 263: Fire-resistance rating standard for assemblies.
  • NFPA 221: Standard for fire walls and fire barriers.
  • AISC: For steel structures.

Factors Influencing Fireproofing Thickness:

  • Fire-resistance rating: Higher fire-resistance ratings require more thickness.
  • Material type: SFRM, intumescent coatings, and other materials have different thickness requirements.
  • Element type: Steel columns, beams, or floors may require different thicknesses.
  • Section factor: For steel, the Hp/A ratio affects how much fireproofing is needed.
  • Environmental conditions: Outdoor or industrial environments may require additional thickness.

By following these guidelines and consulting with manufacturers’ fireproofing thickness charts, you can accurately calculate the thickness required for fireproofing materials based on your project needs and applicable codes.

Box Culvert Design

Box culvert design according to IRC 6 (Standard Specifications and Code of Practice for Road…

Read More
Almost there!
We are confirming your order with